How do I reset my spa power controller?

How do I reset my spa power controller?

The controller can only be reset by pushing the UP, DOWN and PUMP buttons simultaneously. The controller will remain in an error condition even when reset at mains power, controller will only continue normal operation after the UP, DOWN and PUMP buttons are pushed simultaneously (see below).

How do I reset my quip spa?

To Reset the SP400/600/601 and Xcelsior Spa Pool System wait a minimum of 20 minutes to allow the heater tube/area to cool. Then press the down, up and pump buttons all simultaneously and hold for 3 seconds. To Reset the SP800 & SP1200 wait a minimum of 20 minutes to allow the heater tube to cool.

How do I fix error 6 on my spa?

How to Reset Error 6 (Thermal Cut Out/No Flow).

  1. Turn the spa OFF.
  2. Remove filters from the spa and give them a clean.
  3. Remove air locks by bleeding the barrel union on the pumps (You may have more than one pump – please check).

How do I fix error code h2o on a spa?

Turn off the spa and allow time for the water to cool. 3. Press the “UP”, “DOWN” and “PUMP” buttons simultaneously. The Spa may reset and be back to normal operation.

What does F6 mean on hot tub?

The Big List of Spa and Hot Tub Error Codes

CODE ERROR CODE DESCRIPTION
F4 8 hours daily filtration; system message, not an error
F6 12 hours daily filtration; system message, not an error
F Fahrenheit, used to indicate panel is in Fahrenheit mode; system message, not an error
FB-ER Fiber optic error; accent lighting

What does Error 6 mean on a spa pool?

Thermal Cut Out Tripped
Error 6 – Thermal Cut Out Tripped This error indicates that the safety electromechanical over temperature cut out on the heater has operated.

What does CL mean on hot tub?

Current time of day
The Big List of Spa and Hot Tub Error Codes

CODE ERROR CODE DESCRIPTION
CL Current time of day; system message, not an error
COL Cool – water is 20°F below set point; system message, not an error
CoLd Cold – water is 40°F or less; system should self-start the circulation pump and heater

How do I reset my Sapphire Spa?

In the past when a controller has entered an error condition it has been possible to reset the controller by turning the power to the controller off then on again. The controllers are now reset differently, in the event of an error condition the controller can now be reset by pushing a combination of touch pad buttons.

How do you reset a Beachcomber hot tub?

You can reset by pushing any button once the heater cools down. Verify that the knife valve located on the heater’s return side is closed – once verified it’s closed, be sure all the knife valves are in the open or up position.

How do I know if my hot tub control panel is bad?

Spa Control Panel Displays Incorrectly

  1. Error messages or error codes may indicate the problem.
  2. Flickering display may indicate low voltage from transformer.
  3. Partial display may indicate dirty contacts or moisture.
  4. Blinking lights or flashing — indicates a system reset is needed.

What does PR mean on Beachcomber hot tub?

priming mode
Beachcomber Hot Tub Error Codes

Message Meaning
Pr This happens when the hot tub unit is actuated for the first time; eventually it goes into priming mode
–F / –C Means unknown temperature.
Std/ St STANDARD Means hot tub unit is functioning in Standard Mode.
Ecn/ Ec ECONOMY Means hot tub unit is functioning in Economy mode.

How do I know if my spa power 600 controller is bad?

If left on the light will automatically switch off after 30 minutes. The Spa Power 600 controller has extensive self diagnostic capabilities. In the event of a problem it will indicate an error number according to the nature of the problem. The error numbers and their meanings are listed below.

What do I do if my SP600 is displaying an error?

If there is still a problem then contact your spa pool reseller. This error indicates that the digital temperature sensor in the heater or pool has detected a temperature of 45 C or more. This may not be a problem with the SP600, it may be caused by excessive pump use in hot weather, or pump failure.

What does error 6 mean on my spa power 500?

This is not necessarily a problem with the Spa Power 500 itself. It might be caused by excessive pump use during hot weather or by disconnection or failure of the pump. Error 6 = THERMAL CUT OUT TRIPPED. This error indicates that the safety electromechanical over temperature cut out on the heater has operated.

Why does my spa power 500 keep cutting out?

This is not necessarily a problem with the Spa Power 500 itself. It might be caused by high temperatures during shipping, e.g. in the back of a sealed truck, or by disconnection or failure of the pump. This cut out can be reset by pushing the reset button on the lid of the controller. Error 7 = STUCK RELAY.